Free water heater size calculator: find the first hour rating your household needs from its busiest hour, plus tankless flow rate, kW and amp sizing.
This water heater size calculator turns the hot water your household actually uses into the size of heater it needs, using the peak hour demand method published by the U.S. Department of Energy: add up every hot water use that can happen in your busiest hour, and size the tank so that its first hour rating matches the total.
Two machines need two different numbers. A storage tank is sized by first hour rating (FHR), the gallons it can deliver in one hour starting from a full tank, printed at the top left of the yellow EnergyGuide label. A tankless unit stores nothing, so it is sized by the gallons per minute it can heat through the temperature rise you need.
For a tank, count the uses in the busiest hour: showers at 10 gallons each, sink uses at 4, dishwasher loads at 6 and laundry loads at 7. The total is your peak hour demand. It is not the tank's nominal size, because the burner or element keeps reheating water while the tank is being drawn, so a 50-gallon gas tank often carries a first hour rating of 80 gallons or more. Match the label figure, not the tank volume.
For a tankless unit, add the flow rate of every fixture that can run at once and enter the temperature rise from your incoming water to your setpoint. The calculator returns the heating power in kW and BTU per hour, and the current the unit draws at 240 V. Treat the result as a first sizing estimate, then confirm the model, the gas line or the electrical circuit with a licensed plumber or electrician.
Compare the first hour rating with the figure printed on the EnergyGuide label. It is not the same as the tank's nominal size.
Size by first hour rating, not by tank volume. Add up the hot water uses that can happen in your busiest hour, for example 3 showers, a dishwasher load and a laundry load, which is 30 + 6 + 7 = 43 gallons, then pick a model whose first hour rating matches or exceeds that figure. It is printed at the top left of the EnergyGuide label. This calculator charges every sink use at 4 gallons, the larger of the two figures on the Department of Energy worksheet, so its total is slightly conservative.
No. The tank holds its nominal volume, but the burner or element reheats water while the tank is being drawn, so the first hour rating is always higher. A 50-gallon gas water heater commonly reaches 80 gallons or more in the first hour, while a 50-gallon electric unit recovers more slowly. That is why the EnergyGuide figure, not the capacity printed on the box, is the number to compare with your peak hour demand.
By flow rate at a temperature rise. Add the GPM of every fixture that can run at the same time and multiply by the rise from incoming water temperature to your setpoint; the sizing rule manufacturers publish is kW = GPM x rise / 6.83. Two showers and a dishwasher at 5.5 GPM with a 45 °F rise need about 36 kW, which is why whole-house electric tankless units are usually split across several 240 V circuits.